Window Web Hosting houses their servers with The Planet which currently owns and operates two state-of-the-art data centers in Dallas, Texas, offering complete redundancy in power, HVAC, fire suppression, network connectivity, and security. With over 53,000 sq ft of raised floor between the two facilities, The Planet has an offering to fit any need. Our product offerings include private caged suites, cabinets, half-cabinets, tri-cabinets, and rackspace by the Unit. The datacenter facility sits atop multiple power grids driven by TXU electric, with PowerWare UPS battery backup power and dual diesel generators onsite. Our HVAC systems are condenser units by Data Aire to provide redundancy in cooling coupled with ten managed backbone providers. Twelve more third party backbone providers are available in the building via cross connect. Fire suppression includes a pre-action dry pipe system including VESDA (Very Early Smoke Detection Apparatus) with over 700 smoke detectors between the two facilities.

   
  DLLSTX2, Dallas, TX
  DLLSTX4, Downtown, Dallas, TX
  - 60,000 sq. ft. facility
- 35,000 sq. ft. of raised floor
- (21) 26-ton Data Air AC units
- Very Early Smoke Detection Apparatus (VESDA)
- Pre-action dry pipe sprinkler system
- Over 500 smoke detectors
- Simplex security badge entry/exit on all doors
- Multiple TXU electrical grids
- 4800 amps of 480v input power
- 3 main transfer switches
- (6) 500KVA Powerware UPS units with 90 batteries per unit
- Standalone PDUs at each cabinet row
- 1-megawatt generator (2000-gallon tank)
- 1.5-megawatt generator (2200-gallon tank)
- DataTrax monitoring software for all data center infrastructure
  - 22,000 sq. ft. facility
- 18,000 sq. ft. of raised floor
- (12) 26-ton Data Air AC units
- Very Early Smoke Detection Apparatus (VESDA)
- Pre-action dry pipe sprinkler system
- Over 220 smoke detectors in an integrated system
- Simplex security badge entry/exit on all doors to facility
- TXU fault tolerant electrical grid
- 2000 amps of 480v input power
- 1 main transfer switch
- (2) 500KVA Powerware UPS units with 90 batteries per unit
- Standalone PDUs at each cabinet row
- 1.5-megawatt generator (2200-gallon tank)
- DataTrax monitoring software for all data center infrastructure
     